OwnCalculate

Understand the model

A1C Calculator

Use the documented equation to estimate the corresponding average glucose in supported units from an entered A1C value.

Calculation mode

Both modes use the same calculation. Learn mode adds an explanation after a valid result; it does not change your inputs or answer.

Enter a percent, such as 7 for 7%. The result includes estimated glucose in both supported units.

Calculations run in this browser. Your entries are not saved or sent.

Convert between A1C and estimated average glucose

Use the documented equation to estimate the corresponding average glucose in supported units from an entered A1C value.

How to use this calculator

  1. Enter HbA1c as a percentage from 4 to 12, such as 7, not 0.07.
  2. Calculate estimated average glucose in both mg/dL and mmol/L; no unit selector or reverse-conversion input is needed.
  3. Read the clinical caution with the estimate; compare personal laboratory interpretation with a qualified clinician.

Methodology and assumptions

For H percent HbA1c, estimated average glucose is 28.7H−46.7 mg/dL. The corrected mmol/L regression is 1.5944H−2.594. These are population regression relationships, not direct individual measurements or a diagnosis. The mmol/L result uses that corrected equation directly, not a new conversion from a rounded mg/dL display.

Precision and rounding

Both glucose outputs round to one decimal place, ties away from zero. Each is calculated from the entered HbA1c, not from the other rounded output.

Worked example

At H=7: mg/dL=28.7×7−46.7=200.9−46.7=154.2. Separately, mmol/L=1.5944×7−2.594=8.5668, displayed 8.6. The figures illustrate the specified equations, not patient validation.

Reference examples are specification evidence only; they do not claim that this interface or calculation engine has been tested.

Interpreting the result

Individual relationships vary and laboratory A1C interpretation depends on clinical context. The calculator does not diagnose diabetes or recommend treatment.

Supported input is percent HbA1c, not IFCC mmol/mol. Values outside 4–12% are rejected rather than extrapolated. Red-cell conditions, assay differences and individual variation can affect interpretation; no treatment target or reverse A1C estimate is provided.

Common mistakes

  • Enter A1C as a percent, not a fraction.
  • Select the correct glucose unit.
  • Estimated average glucose is not a current finger-stick or CGM reading.
  • Do not use this tool to change medication or treatment.

Frequently asked questions

Is estimated average glucose a measured result?

No. It is an estimated conversion from the entered A1C.

Does this diagnose diabetes?

No. Diagnosis requires clinical interpretation and appropriate testing.

Why can sources show slightly different unit values?

Published tables and conversion equations can differ through rounding; the tool follows its stated equation.

Can I enter mmol/mol?

Only the units specifically supported by the input contract are accepted.

Should treatment be changed based on this result?

No. Discuss results and treatment with a clinician.

Can I enter an IFCC result such as 53 mmol/mol?

No. The input requires percent HbA1c; do not relabel or insert a different laboratory unit.

Sources and further reading

These references support the documented method or context. They do not imply application testing or endorsement.